Impac IS 140 and IGA 140 Series Pyrometer

Highly Accurate Digital Infrared Pyrometer with Multiple Interface Options, 220 to 3500°C

Impac IS 140 and IGA 140 series include pyrometers with focusable optics for non-contact temperature measurement of metal with a wide range of interface options.

  • Temperature ranges between 220 and 3500°C
  • Available with three different focusable optics
  • Short response times <1 ms
  • Extremely small spot sizes min 0.35 mm
  • Available with Ethernet, Profinet, and Profibus interfaces

Enquire Now

"*" indicates required fields

Name*
This field is hidden when viewing the form
This field is for validation purposes and should be left unchanged.

Temperature Ranges

Impac IS 140
 550 to 1400°C (MB 14)
600 to 1600°C (MB 16)
650 to 1800°C (MB 18)
550 to 1800°C (MB 18L)
750 to 2500°C MB 25)
900 to 3300°C (MB 33)
650 to 1400°C (MB 14, forging version)
750 to 3500°C (MB 35L)
1100 to 3500°C (MB 35L, 0.676 µm version)
1000 to 2000°C (MB 20, 0.55 µm version)
(Spectral Range 0.7 to 1.1 µm)

Impac IGA 140
300 to 1300°C (MB 13)
350 to 1800°C (MB 18)
450 to 2500°C (MB 25)
220 to 1150°C (MB 11.5L) 
250 to 1350°C MB 13.5L)
300 to 2000°C (MB 20L)
350 to 2500 °C (MB 25L)
300 to 3000 °C (MB 30L)
(Spectral Range 1.45 to 1.8 µm)

Typical Applications

  • Preheating
  • Annealing
  • Tempering
  • Welding
  • Forging
  • Hardening
  • Sintering
  • Melting
  • Soldering
  • Rolling
  • Brazing
  • Normalising

Interface & Communication

Analog Output
Adjustable 0 to 20 mA or 4 to 20 mA, linear (via digital interface)

Digital Interface
Switchable inside the pyrometer: RS232 or RS485 addressable, half duplex; baud rate up to 115 kBd. Alternatively: Profibus, Profinet, or Ethernet

Related Products

What our customers say…

When rebuilding one of our clamshell furnaces we opted for four Impac ISR 6 pyrometers for precise temperature measurement. I am very impressed with the quality of every component from the cooling jackets to the sensors themselves, which seem exceptionally well made. I would not hesitate to contact LIMAB in the future for any other applications that I may need help/equipment for.